• Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch
  • Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch
  • Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch
  • Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch
  • Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch

Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch

Type: High-voltage
Structure: Three-column Disconnector
Installation: Indoor High-voltage
Operation: Manual
Number of Poles: Three Pole
Structure of Operating: Manual
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FKN12
Certification
ISO, ISO9001
Brand
Sk
Rated Current
630A
Rated Voltage
12kv
Rated Frequency
50Hz
Opening Time of Fuse Trigger
30-40ms
Opening Time of Tripper Trigger
40-50ms
Trademark
SK
Origin
China
HS Code
8536909000
Production Capacity
5000

Product Description

Description:
FN12-12 3 poles indoor high voltage load switch with fuse holder & earthing

Application
It is used in the ring network city distribution and industrial equipment of 12KV and three-phase AC 50Hz to cortrol load and
short-circuit. Because the switch with fuse protecting transformer etc more reliably than circuit breaker. It is especialy
suitable for ring network clouble radial distribution and package substation.
Standard
a. GB3804-90 <<3-63KV AC H.V load switch>>.
b. GB16926-1997 <>(eqv, IEC62271-2002).
c. GB1995-89 <>.

Operating environmental conditions:
1.Altitude: ≤1000m
2.ambient air temperature: not higher than +40°C,not lower than-25°C
3.Relative humidity: daily mean is not more than 95%, monthly mean is not more than 90%
4.Earthquake intensity: not more than 8°
5.no fire, explosion hazard, chemical etching and intense vibration
6.Pollution grade: II
7. Ambient air shouldn't be polluted by corrosive or flammable gas and vapor.
 
NO.
Items
Unit
Data
FN12-12D/630
FN12-12(R)D/630
1
Rated voltage
KV
12
2
Rated frequency
Hz
50
3
Rated Current
A
630
1250
4
Lightning impulse withstand voltage
KV
To earth and phase to phase 75, isolation fracture 85
5
1 min power frequency withstand voltage
KA
To earth and phase to phase 42, isolation fracture 48
6
Rated thermal stability current
KA
20(4s)
7
Rated dynamic current
KA
50
8
Rated dosing current (peak)
KA
50
50
9
Rated short circuit breaking current (Expected value)
KA
 
31.5
10
Maximum at critical breaking current
A2S
According to the fuse characteristic curve
11
Minimum breaking current
KA
According to the fuse characteristic curve
12
Rated transfer current
KA
 
1.5
13
Maximum breaking current (reference value)
KA
1.8
14
Breaking the capacity of the no-load transformer
KVA
1250
15
Rated cable charging current
A
10
16
Rated active load current breaking times
Times
>100
17
The impactor touches the load switch opening time
S
 
>0.06
18
Earthing switch thermal stability current
KA
20(2S)
19
Earthing switch thermal stability current (peak)
KA
50
20
Motor operating power supply voltage
V
AC DC 110, 220
Fkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break SwitchFkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break SwitchFkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break SwitchFkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break SwitchFkn12 Fn12-12D630 12kv 33kv 630A Lbs Indoor High Voltage Load Break Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now